<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="research-article" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">Science and Innovations in Medicine</journal-id><journal-title-group><journal-title xml:lang="en">Science and Innovations in Medicine</journal-title><trans-title-group xml:lang="ru"><trans-title>Наука и инновации в медицине</trans-title></trans-title-group></journal-title-group><issn publication-format="print">2500-1388</issn><issn publication-format="electronic">2618-754X</issn><publisher><publisher-name xml:lang="en">FSBEI of Higher Education SamSMU of Ministry of Health of the Russian Federation</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">21535</article-id><article-id pub-id-type="doi">10.35693/2500-1388-2016-0-3-39-44</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Articles</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Статьи</subject></subj-group><subj-group subj-group-type="article-type"><subject>Research Article</subject></subj-group></article-categories><title-group><article-title xml:lang="en">INTEGRAL ALGORITHM OF P300 RECOGNITION IN EEG FOR BCI APPLICATION</article-title><trans-title-group xml:lang="ru"><trans-title>ИНТЕГРАЛЬНЫЙ АЛГОРИТМ РАСПОЗНАВАНИЯ КОМПОНЕНТЫ Р300 В ЭЭГ-СИГНАЛЕ ДЛЯ ПРИМЕНЕНИЯ В НЕЙРОКОМПЬЮТЕРНОМ ИНТЕРФЕЙСЕ</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Agapov</surname><given-names>S N</given-names></name><name xml:lang="ru"><surname>Агапов</surname><given-names>С Н</given-names></name></name-alternatives><bio xml:lang="en"><p>specialist of the laboratory of mathematical processing of biological information, IT Universe LLC.</p></bio><bio xml:lang="ru"><p>сотрудник лаборатории математической обработки биологической информации компании IT-Universe.</p></bio><email>sergeyagapov@it-universe.ru</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Bulanov</surname><given-names>V A</given-names></name><name xml:lang="ru"><surname>Буланов</surname><given-names>В А</given-names></name></name-alternatives><bio xml:lang="en"><p>head of the laboratory of mathematical processing of biological information, IT Universe LLC.</p></bio><bio xml:lang="ru"><p>руководитель лаборатории математической обработки биологической информации компании IT-Universe.</p></bio><email>vb@it-universe.ru</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Zakharov</surname><given-names>A V</given-names></name><name xml:lang="ru"><surname>Захаров</surname><given-names>А В</given-names></name></name-alternatives><bio xml:lang="en"><p>PhD, associate professor of the Department of Neurology and Neurosurgery, head of the Laboratory of Neurointerface of the Centre for breakthrough research «IT in Medicine», SSMU</p></bio><bio xml:lang="ru"><p>к.м.н., доцент кафедры неврологии и нейрохирургии СамГМУ.</p></bio><email>zakharov1977@mail.ru</email><xref ref-type="aff" rid="aff2"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Sergeeva</surname><given-names>M S</given-names></name><name xml:lang="ru"><surname>Сергеева</surname><given-names>М С</given-names></name></name-alternatives><bio xml:lang="en"><p>PhD, associate professor of the Department of Physiology with the course of life safety and medicine of catastrophes, head of the Laboratory of Applied Neurophysiology of the Centre for breakthrough research «IT in Medicine», SSMU.</p></bio><bio xml:lang="ru"><p>к.б.н., доцент кафедры физиологии с курсом БЖД и медицины катастроф</p></bio><email>marsergr@yandex.ru</email><xref ref-type="aff" rid="aff2"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Pyatin</surname><given-names>V F</given-names></name><name xml:lang="ru"><surname>Пятин</surname><given-names>В Ф</given-names></name></name-alternatives><bio xml:lang="en"><p>PhD, professor, head of the Department of Physiology with the course of life safety and medicine of catastrophes, head of the Department of Neurointerface and Applied Neurophysiology of the Centre for breakthrough research «IT in Medicine», SSMU</p></bio><bio xml:lang="ru"><p>заведующий кафедрой физиологии с курсом БЖД и медицины катастроф, начальник отдела нейроинтерфейсов и прикладной нейрофизиологии ЦПИ «Информационные технологии в медицине», д.м.н., профессор.</p></bio><email>pyatin_vf@list.ru</email><xref ref-type="aff" rid="aff2"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">IT-Universe (Samara)</institution></aff><aff><institution xml:lang="ru">ООО «IT Universe» (Самара)</institution></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="en">Samara State Medical University</institution></aff><aff><institution xml:lang="ru">ФГБОУ ВО «Самарский государственный медицинский университет» Минздрава России</institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2016-09-15" publication-format="electronic"><day>15</day><month>09</month><year>2016</year></pub-date><volume>1</volume><issue>3</issue><issue-title xml:lang="en">NO3 (2016)</issue-title><issue-title xml:lang="ru">№3 (2016)</issue-title><fpage>39</fpage><lpage>44</lpage><history><date date-type="received" iso-8601-date="2020-03-10"><day>10</day><month>03</month><year>2020</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; 2016, Agapov S.N., Bulanov V.A., Zakharov A.V., Sergeeva M.S., Pyatin V.F.</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; 2016, Агапов С.Н., Буланов В.А., Захаров А.В., Сергеева М.С., Пятин В.Ф.</copyright-statement><copyright-year>2016</copyright-year><copyright-holder xml:lang="en">Agapov S.N., Bulanov V.A., Zakharov A.V., Sergeeva M.S., Pyatin V.F.</copyright-holder><copyright-holder xml:lang="ru">Агапов С.Н., Буланов В.А., Захаров А.В., Сергеева М.С., Пятин В.Ф.</copyright-holder><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">https://creativecommons.org/licenses/by/4.0</ali:license_ref></license></permissions><self-uri xlink:href="https://innoscience.ru/2500-1388/article/view/21535">https://innoscience.ru/2500-1388/article/view/21535</self-uri><abstract xml:lang="en"><p>Aim - developing the integral algorithm of recognition of the evoked potential (ERP-response) to a target visual stimulus and testing of the proposed algorithm on the wireless 5-channel electroencephalograph Emotiv Insight with “dry” electrodes. Materials and methods. The objects of the study were the EEG records of five volunteers. Were used 5-channel wireless EEG headset Emotiv Insight, self-developed software «eSpeller», software environment MathWork® MATLAB R2015a. Results. It was found that the proposed integral algorithm of recognition of electrical activity of the cerebral cortex to a target visual stimulus shows the accuracy of the detection from 71.5% to 90.6% with the average value 80.1+7.2%, using EEG headset Emotiv Insight. Conclusion. The algorithm shows a high level of reliability of recognition of evoked potential to a target visual stimulus, does not require large computing power, sophisticated classification methods and machine learning. The testing of the algorithm suggests the possibility of using the electroencephalograph Emotiv Insight with "dry" electrodes in the development of BCI.</p></abstract><trans-abstract xml:lang="ru"><p>Цель исследования - разработка интегрального алгоритма распознавания вызванного потенциала (ERP-отклика) на целевой визуальный стимул и проверка работоспособности предложенного алгоритма на беспроводном 5-канальном электроэнцефалографе Emotiv Insight с «сухими» электродами. Материалы и методы. Объектами исследования были ЭЭГ-записи пяти испытуемых-добровольцев. В работе использовались беспроводной 5-канальный электроэнцефалограф Emotiv Insight с «сухими» электродами, самостоятельно разработанное ПО «©Speller», программная среда MathWork® MATLAB версии R2015a. Результаты. Разработанный интегральный алгоритм распознавания электрической активности коры головного мозга на предъявление целевого визуального стимула показывает достоверность распознавания от 71,5% до 90,6%, среднее значение - 80,1+7,2%. Заключение. Представленный алгоритм демонстрирует высокий уровень достоверности распознавания вызванного потенциала на целевой визуальный стимул, не требует больших вычислительных мощностей, сложных методов классификации и машинного обучения. Апробация предложенного алгоритма указывает на возможность применения электроэнцефалографа Emotiv Insight с «сухими» электродами в ней-рокомпьютерном интерфейсе.</p></trans-abstract><kwd-group xml:lang="en"><kwd>P300</kwd><kwd>EEG</kwd><kwd>evoked potential</kwd><kwd>ERP</kwd><kwd>P300</kwd><kwd>integral algorithms</kwd><kwd>BCI</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>ЭЭГ</kwd><kwd>вызванные потенциалы</kwd><kwd>интегральные алгоритмы</kwd><kwd>нейрокомпьютерный интерфейс</kwd></kwd-group></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Пятин В.Ф., Колсанов А.В., Сергеева М.С., Захаров А.В., Антипов О.И., Коровина Е.С., Тюрин Н.Л., Глазкова Е.Н. Информационные возможности использования мю- и бета-ритмов ЭЭГ доминантного полушария в конструировании нейрокомпьютерного интерфейса. Фундаментальные исследования. 2015; 2(5):975-978. Доступно по: http://www. fundamental-research.ru/ru/article/view?id=36967. Ссылка активна на 21.08.2016 г</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>Edlinger G, Allison BZ, Guger C. How many people can use a BCI system? Clinical Systems Neuroscience. 2015:33-66</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>Birbaumer N, Hinterberger T, Kuebler A,. Neumann N. The thought-translation device (TTD): Neurobehavioral mechanisms and clinical outcome. IEEE Trans. NeuralSyst. Rehabil. Eng. 2003.vol. 11(2):120-123</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>Norcia AM, Appelbaum LG, Ales JM, Cottereau BR, Rossion B. The steady-state visual evoked potential in vision research. A review, J. Vis., 2015, vol. 15 (6):4</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>Luck SJ. An Introduction to the Event-Related Potential Technique. 2005, vol. 78(3)</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>Krusienski DJ, Sellers EW, Cabestaing F, Bayoudh S, McFarland DJ, Vaughan TM, Wolpaw JR. A comparison of classification techniques for the P300 Speller. J. Neural Eng., 2006.vol. 3(4):299-305</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>Sun S, Zhou J. A review of adaptive feature extraction and classification methods for EEG-based brain-computer interfaces. Proceedings of the International Joint Conference on Neural Networks, 2014:1746-1753</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>Fazel-rezai R, Gavett S, Ahmad W, Rabbi A, Schneider E. A Comparison among Several P300 Brain-Computer Interface Speller Paradigms. Clin. EEG Neurosci. 2011.vol. 42(4):209-213</mixed-citation></ref></ref-list></back></article>
